softenerparts This simple time clock controller gives the installer the option of an every day up to 99 day regeneration frequency. Here are a few common problems for the Autotrol 460i and similar water softeners. Fleck 5810. R Use the UP and DOWN buttons to advance to the desired regen time. The hardness of water that goes into my home measures 10. GE Water softeners with Custom Select TM blending valve allow you to select how soft you want your water. I have an autotrol 440i watersoftener. held open by foreign matter or particle. Possible Cause.

A regeneration or backwash cycle must complete to sanitize a water softener. 268 460 OWNERS MANUAL - Nugen Pure Water Systems.

The 460i is a metered (demand) control that is easy to set and easy to operate. In time-initiated regeneration, the clock on the control valve is typically set to have the system regenerate after a certain number of days and at a time of day with low water usage (default setting is often 2 am).

Upload; MANUAL REGENERATION: NOON 3AM PRESS KNOB AND TURN CLOCKWISE TO START RELEASE 9AM 6 6AM Autotrol 255-460i Manual December 2019 58. Our Water Treatment Components Business strives to offer the highest quality valves, tanks and filtration components to OEMs building water treatment solutions. Fleck 2510 Manual Regen Valve. Supplier Part #: CAF-10T. Autotrol 460i and 460TC ConTrol SySTem. . 5800 XTR2 Manual.

depress the indicator knob (Figure 12).

Fleck 5600 metered water softener manual. autotrol 460i performa 440i Fleck 5600 econominder manual regeneration. To change the regen time, press SET - causing 2:00 to flash. a. 263 is a filter valve while 268 is a softener valve. all other functions are operated by water pressure. System indexes manually with or without power to any one of its service or regeneration positions. aut You can also save on salt, water, and energy by using up to 50% less detergent for laundry and dishwashing*, using up to 34% less salt and up to 35% less water during regeneration.**. All Water Softener Service Parts, Autotrol Common Parts Pentair Autotrol Transformer 230-240v 12v 50hz P/N 1000813 - Prices from 37.20 - Incl.

Part# 1040534. Water softeners can take as long as 90 minutes to regenerate. 760. Grain 60 000 S Ce Model 2P45M Grain F Iron Removal Flcv Rates 10.5 Iron Removal Service Flow Rates 12.0 m 45,000 26" 15" 52" NOTE: Based on Clear Water Iron NOTE: Based on Clear Water Iron ADDITIONAL OPTIONS AVAILABLE Autotrol& ReadySoftTM Alternating System QTY: Add to Cart.

Autotrol Bypass Add on. Operates the 255 valve. For the 460i, simply depress the indicator knob (Figure 6). My Account Home; Autotrol 460i Timer Only More Info. The Autotrol 255/460i Demand Water Softener Control system for 3/4 inch plumbing is reliable and durable, providing you with a long life of hassle free soft water. Series 255 Valve / 400 Series Controls. Product. Pentair Residential Filtration brings homeowners the best choice in residential water treatment systems. (See manual regeneration sections for each controls manual operation.)

Rotor & Disc Sears, Kenmore, GE, North Star, Tap Works, Ecowater 7199232 Replaces Part # 7103964 G.E. Autotrol 255 400 series 460i Metered replacement Controller 118 min regen. Telephone: +1.847.888.6900 Facsimile: +1.847.888.6924 E-mail: info@swtwater.com https://www.swtwater.com Last Updated: August 27, 2018August 27, 2018 Performa FA Valve with 400 Series Control. Bypass valve in bypass. Autotrol. Returned to find no softwater in shower.

Part # WS26X10002. IDOCPUB. We configure and assemble units featuring valves from Clack, Fleck and Autotrol. Highlands) If you are ordering from outside the UK, please call us on +44 (0)1948 710699 for our most competitive shipping rate Product details:-. PRODUCT DOCUMENTATION Autotrol255 Valve/400 Series Service Manual Autotrol 460i and 460tc Installation/Operation Manual Autotrol 460TC Timer Spec Sheet FEATURES AND 4001232 510.32CAD Add to Cart Quick view. 8.25; Fleck Water Mtr Cover; Fleck Plastic Plug, BLFC; Fleck Main Drive Gear; Harness; Performa ProSoft with 960 Series Control. Home (current) Explore Explore All. PRODUCT DOCUMENTATION Autotrol255 Valve/400 Series Service Manual Autotrol 460i and 460tc Installation/Operation Manual Autotrol 460TC Timer Spec Sheet FEATURES AND 4001232 510.32CAD Add to Cart Quick view. Manual Regeneration Electricity is used only to run the control and to rotate the camshaft. The 460i is a metered (demand) control that is easy to set and easy to operate. / max.) download Report . To accept this time, press the DOWN button to move to step 5. . Step 2: Proceed with a normal regeneration cycle. The Autotrol bypass valves are constructed of lightweight Noryl to allow easy transfer from the service to the bypass position. manualzz autotrol 460i Autotrol Service Manuals/Spec Sheets . Fits on older Autotrol 150,155,160, 163, 168 Valves, and newer 255, 263, and 268 Valves that have 440, 440i, 440iHV or 460i timers now. prices in quality water softeners. Question about the product. $149.50 to $399.00 (2 offers) - Buy AUTOTROL 255-760 Logix Metered Grain Softener Efficient Salts 48 000 Saver . Autotrol 740 760 255-Performa Series Manual. 400 Series 440i Time Clock Value priced, reliable mechanical control Time-clock regeneration Set it and forget it 12-volt or 120-volt versions available 6- or 7-day regeneration Operates 255, 263, 268 valves Water Softener Parts. 460TC Initial Set Up of the Autotrol Timer that replaced the 440440i,440iHV timers in mid-2011. 6.99. Uploaded by: Greg Reyneke; 0; 0; Manual Regeneration Electricity is used only to run the timer and to rotate the camshaft.

SKU. Add to Cart. autotrol 255 valve / 400 series controls service manual. In that case, you need to reset the timer and clock. UOM : EA. The controller is great for residential and light commercial applications. I figured you could set it for certain days, but it clearly states the unit is configured to run at 2:00AM every day. doc zz. Fleck 4650. Step 4: Set Day of Week Time & Day Regen Time & Day REGEN again to initiate a second manual regeneration. 255-440i/460i. Water softener is old and needs to be replaced. 255. I own an Autotrol 460i water softer. of salt) or brine line after regeneration. Water Softeners and Air Filtration Systems - Autotrol 255 Valve w/ 460i Control - Not regenerating enough? Since salt must be added periodically to the brine tank, the location should be easily accessible. Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation. b.Valve stem return spring weak. Autotrol 460i controller (manual here) 0.75 ft 3 resin tank; Two adults in the house, average 3,300 gallons of soft water usage per month / 55 gallons per person per day. Fleck 5800. To begin with, check the timer of Autotrol 460i. It could be stuck or the clock might not be working. In that case, you need to reset the timer and clock. You have to open the jumper to access the timer. Use a small nail or tweezer to open the jumper first. . 4-9.

Emptied all salt in tank, cleaned everything. A compression fitting that connects the brine tank to the water softener valve is not properly installed or tightened. This is a timer replacement for NovRam, 440, 460, and 460i Timer Assemblies. To flush out any remaining cleaner in your system, turn on the nearest faucet and let it run for 10 minutes. Autotrol 255 Series 400 and 700 Logix valves. COUNTERCLOCKWISE to START to initiate a regeneration. Click here for the 2021 Catalog Softeners, POE Equip. Autotrol 742/762 255 & Performa (263, 268, 268 FA) Manual. REMOTE REGEN CABLE: 1239979: KIT, REMOTE START/LOCKOUT: 3020228: SENSOR Y-CABLE ASSEMBLY, LOGIX TWIN: With the ways to solve them-Control Regeneration Problems Your water softener is supposed to clean itself. This process will repeat itself at least once a week, at minimum. This is a manual for the upgraded version of the 155.. The 760 includes single programming, with a 28-day variable reserve feature and the ability to change the time of regeneration. On 2018-08-19 by tom. PRODUCT DOCUMENTATION Autotrol255 Valve/400 Series Service Manual Autotrol 460i and 460tc Installation/Operation Manual Autotrol 460TC Timer Spec Sheet FEATURES AND 4001232 510.32CAD. Autotrol Performa ValVe 460TC BRINE/ SLOW RINSE BACKWASH FAST RINSE/ REFILL CONDITIONED WATER MANUAL REGENERATION: PRESS BUTTON & RELEASE PRESS TO SETTIME. AUTOTROL. Just to address Garry's questions I know that the softener is producing soft water, and we haven't run out of soft water before. Autotrol 255/460 TC Timer 6 Days Regeneration $ 299.00 Autotrol 255460i Metered On Demand Control $ 379.00. 255-740/760. b.Replace o-ring. Usually 4 to 8 gallons of brine water is needed to backwash the average water softener. Check your owners manual to set brine float to proper height. Please Log In. Includes Autotrol 268 Performa 1" valve with 440 6-day timer or 460i microprocessor, 3/4" tube adapters, blue polyglass mineral tank, and standard mesh resin. Effects of Backwash Water and Regeneration Wastes from Household Water Conditioning Equipment on Private Sewage Disposal Systems. Also cleaned injector (that was pretty dirty and clogged). back to main Service Manual Page . If a days usage is more than double the current average, the computer anticipates that a second day of high usage is likely to occur. (196.00 Ex VAT) *Incl. View in Catalog. 460i, 740 Logix, 760 Logix and 762 Logix. 1030000 460i Timer Assembly w/ Transformer included (120v to 12v) more info. Autotrol Osmonics offers a full range of valve controllers to meet all residential water-conditioning applications.

Our Services ; News & Events; 90 days free exchange warranty. When you are done, just remember to turn the regeneration knob clockwise back to its original position. Sold by Discount Water Softeners Water usage for EVERY regeneration.

Autotrol 255-460i Manual. of water. John 10:10 Provide the quality water that you deserve at a price that you can afford! (Autotrol 460i). 7.50. 255 Control Valve Spec Sheet Manual says: "controls the amount of salt used per regeneration." This generally happens due to a broken controller or timer. More Info. Autotrol 460TC Replacement Timer Assembly for 440 Series with Transformer 4.5 out of 5 stars 90.

Low or No Water Usage including water softener adjustment of the regeneration or backwash cycle frequency and the water softener salt dose. recommend that you determine the size of your water softener using a value that is 20% less than it's actual capacity.

Click For More Info. To accept this time, press the DOWN button to move to step 5. away obstruction. 7- or 99-day regeneration setting; High efficiency regeneration sequence; 12-volt operation; See owners manual for specific concentrations. Made sure pick up tube was clear. A lot happens during this process. Though both are similar in function, the 256 Autotrol bypass offers simplicity and ease of operation. Time-tested Duraflow flapper technology provides frictionless sealing for longer service life. AUTOTROL 742/762 Control 255 & Performa Series Valves (263, 268, 268FA) Service Manual 3 QUICK START. Water Softeners; Iron Filtration; Home Filtration; Autotrol 255-440i Manual November 2019 62. Brand: AUTOTROL . Fleck 6700.

If a 460i is not regenerating automatically it's usually a stuck turbine wheel. Run some water and look at the display. There should be a blinking light between the two digits. If you do not see a blinking light the controller is not metering water. If it's not metering water it won't regenerate automatically. Check price DoughXpress DM-18NH - Manual Pizza Dou Budget Robot Coupe CL50E Food Processor Slicer Grater; Compare Wusthof Classic Ikon 10-Piece Knife Set wi Cheap The Verona / Magic Mill DLX Mixer - The Ele Cheap Panasonic Prestige 2.2 cu. An Autotrol instruction manual is included with the valve. The inherent reliability for the system means a long life of efficient, trouble-free, uninterrupted soft water luxury. Autotrol 255 LOGIX meter controlled valve, WITH turbine manifold . Add to Cart. Read Full Source standard delivery to all UK Mainland Postcodes. $770.00. VAT & delivery to all UK Mainland Postcodes. The 460i Control provides conditioning efficiency that automatically adjusts to water demands and ensures continuous conditioned water with substantial savings on both salt and water. Autotrol Water Softener and Filter Valves and Parts. Step 4: Set Regen Time Time & Da y Regen Time & Da y Salt SU MO TU WE TH FR SA DA YS Capacity Har dness R 2:00 (AM) is the default time of regeneration. Please Log In. Continuous service flow rate of 15.5 GPM with a backwash of 6 GPM. If a days usage is more than double the current average, the computer anticipates that a second day of high usage is likely to occur. It's an Autotrol with a 460i automatic controller. 2 Rev J TABLE OF CONTENTS LOGIX Autotrol 255-460i Manual [pd49j91d98n9]. Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation. AUTOTROL 440I MANUAL >> READ ONLINE autotrol manual regeneration chem aqua water softener manualautotrol 255 460tc 460tc water softener manual 460i water softener settings Watts Autotrol 255 (400 Series) User Manual 400 series control settings, 440i control Watts Accessories for water. Replacement Autotrol 460i Control Only. Super capacitor for keeping time of day during power outage. Page 2: 460I Electronic Demand System Low or No Water Usage determines if the water conditioner has enough The 460i is programmed to recognize a day of very little remaining capacity to supply the next days needs. Sold by Discount Water Softeners Water usage for EVERY regeneration. Autotrol Performa 263/268 valves. A higher-capacity softener or one that has more features will be more expensive. Autotrol Valve Manuals. Autotrol Is Similar To: 1016182 Autotrol Water Softener Filter Control Valve (37.2% similar) autotrol 255 and perform series water softener filter control valve bypass -operation manual-class 2 TRANSFORMER-120 vac 60 Hz 8 watts used good working condition no damage have some minor scratches on the top cover.(October 25th, 2018); 1033013 Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation. This is of course for a lower spec and capacity model.

Autotrol 255 / 460i microprocessor meter system Meter Based Water Softeners regenerate based on the amount of water used since the last regeneration. GE 960 Series Water Dispenser User Manual. As a custom-assembler of water conditioning systems, we can offer an almost unlimited variety of equipment. Related Manuals for Autotrol Performa 440i Control. Autotrol 255. Figure 1 - Autotrol Series 1265 Bypass Valve Figure 2 - Typical Globe Valve Bypass System Drain Line Connection The 268/760 computer/demand control system for 1" plumbing combines design simplicity with reinforced NORYL construction to provide you with an uncommonly reliable appliance. Vanne 255-460i, lintlligence lectronique au service de lconomie deau. Qty. Fleck 7000. 9000-9100-9500 Manual. 10. therefore, in the event of a power outage, all the. Autotrol Brand 255 Valve Operation, and Maintenance Manual For sales or service questions please contact your local dealer: Your Local Dealer Is: 1018075 Dnsized.fm Page 1 Monday, June 30, 2003 6:16 PM responsible for directing the flow of water during all phases of regeneration. Fleck 5600. Figure 4 Autotrol Series 256 Bypass Valve Figure 5 Typical Globe Valve Bypass System Drain Line Connection 1. Add to Cart. . I put in about 5 gallons of salt water and new salt pellets. Economical price! The timer works fine. It will 20 Replacement Parts for Autotrol Brand 255 Control. When installed the hardness was set to 22 but a recent water test shows hardness is actually 15, and the water feels a bit ?slimy?like it?s over-softened. 3. Autotrol Brand Performa Valve / 400 Series Controls Water Conditioning Control System Home Owner Installation, Operation, and Maintenance Manual For sales or service questions please contact your local dealer: Your Local Dealer Is: 1237853 A.fm Page 1 Series 255 Valve / 960 Control. Specifications: Production Membrane rejection Tank capacity Temperature range Pressure (min. For the 460i, simply Autotrol 460i Metered Conditioner Control. AUTOTROL. However, the cam does not rotate, even in manual regeneration . Our Price US$1,168.70. Home. 7 Manual Regeneration Electricity is used only to run the control and to rotate the camshaft. b.Replace spring. 50 GPD 96% (typical) 4 gallons 40F - 100F 30 - 100 psi Primary advantages: 50 GPD capacity, top quality components and highly attractive pricing. Culligan Water Conditioning Of Tampa Bay 2703 Airport Rd. Read Here Water Softener Installation Guide Effective For All Softeners If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available. Fleck 9000. 1. A. If or no water usage as an abnormality. Ajouter au Panier. (196.00 Ex VAT) *Incl. All other functions are operated by water pressure. The high usage amount will be used as the reserve when the 460i performs its regeneration computation. Includes: Cover and Transformer. QTY: Add to Cart. With the water supply valve completely open, carefully advance the indicator knob COUNTERCLOCKWISE to the center of the BRINE REFILL position. NXT Timer Manual. Performa 400 Owners Manual 1222945. $220.53. Manual: Performa 400 Owners. Depress skipper pin(s) at day(s) for which regeneration is desired. Autotrol Valves Application Notes. Fleck Valve Manuals. . Figure 4 Autotrol Series 256 Bypass Valve Figure 5 Typical Globe Valve Bypass System Drain Line Connection 1. Get Price. Manuals. Turn the softener shutoff valves to the bypass position and start a manual regeneration to relieve internal pressure. In Stock. Nelsen Residential Water Softener Systems. 1018075 Rev I.fm Page 23 Tuesday, February 17, 2004 4:26 PM. Log in ; Registration ; Explore . Autotrol Service Manuals/Spec Sheets; Commercial Service Manuals; Commercial NRO Literature & Manuals; Reverse Osmosis Water Analysis Form; My Account. 2. 103-1040534. Pro Softener Mate Softener Resin Cleaner 113g (4oz) 1-3. SXT Owners Manual. 2. SKU. I(like anybody else) would like to prolong the life of the softener! Depress the indicator knob on the 440i (Figure 10) with a wide-blade screwdriver and turn COUNTERCLOCKWISE to START to initiate a regeneration. Resin Tank Size (in Grains) UPFLOW DOWNFLOW; 24,000 Grains: 24 gallons: 58 gallons: 32,000 Grains: Manuals; Customer & Technical Support; SHOP. all other functions are operated by water pressure. Water Softeners; Iron Filtration; Home Filtration; 1. *This product fits on all older model Autotrol 150, 155, 160, 163, and 168 Valves, as well all newer model Autotrol 255, 263, and 268 Valves that have either the 440, 440i, 440iHV or 460i timers. Solution To begin with, check the timer of Autotrol 460i. Autotrol 255 / 460i microprocessor meter system Meter Based Water Softeners regenerate based on the amount of water used since the last regeneration. (Excl. Nelsen 10" x 54" Backwash Only Filter Unit with C-Series Filter Valve and 3/4" Tube Adapters. 460i-Three simple settings for metered control. Buy in monthly payments with Affirm on orders over $50. The 460i Demand Control The 460i demand control provides your home with conditioned water based on your familys water usage, regenerating only when needed. Pull it out of the motor and set it aside. autotrol 255 valve / 400 series controls service manual. . Control Systems Autotrol 460i Operation And Maintenance Manual. Has large 1" ports for high-flow applications. Up to 3m3/hr flow rate. Checked to find salt tank dry..Did I ruin something by turning the water off? .

Benefits of the Autotrol 255/460i Demand Water Softener Control; Fewer parts - less maintenance; One motor - no additional solinoids needed; No dynamic seals - less chance of leaks The second tank has a mechanical controller (not digital, I can't read the model number, I can provide a picture if needed) and is significantly larger (perhaps twice the size of the first tank). Vannes 255 avec horloge 460i. WQA Certified 255-460i Systems: 255-460i-075-844 255-460i-100-948 Working Pressure: 20-125 psi (1.38 - 8.61 bar) Standard 12 Volt Transformer Input Electrical Rating: 115V 60 hz Optional 12 Volt Transformer Input Electrical Rating: 115V 50 hz, 230V 50 z, 230V 60 hz, 100V 60 hz, 100V 50 hz Operating Ambient Temperature: 34-120F (1-49C) Fleck 2510. Removing 440i or 460i for Servicing . CONTACT INFORMATION: TOLL FREE: 1-877-345-2770 LOCAL TAMPA: 813-832-9293 813-626-9498 EMERGENCY #: 813-244-5185 FAX: 813-620-0174 Operates the 255 valve Autotrol 460i Metered Conditioner Control. Logix 255/760 Meter Water Softener - 40,000 Grain Capacity. d. Defective meter probe. The Autotrol 460i has become a popular name in water softening. Just like any other appliance, the Autotrol 460i can have problems. So, knowing how to solve any problems can be crucial. Solving problems early can massively improve the longevity of your softener. What is the basic Autotrol 460i troubleshooting? Special Price $401.42. Autotrol 255/460i Ctrl 3/4 Lng Rns w/Cvr; Autotrol 255/460i Ctrl 3/4 Elec. Magnum 740/760. On 2018-04-22 - by (mod) - . This economy model demand control will set a new standard for simple and efficient controllers. INSTALLATIONS STARTING AT $100.00 * NEXT DAY INVENTORY * WE BEAT ALL ESTIMATES BY UP TO 10%. The 460i is programmed to react to a sudden increase in water usage. All other functions are operated by water pressure. Images. As mentioned earlier, the softeners resin beads get a flush and are reinvigorated with salt from the brine tank. AUTOTROL 440I MANUAL >> READ ONLINE autotrol manual regeneration chem aqua water softener manualautotrol 255 460tc 460tc water softener manual 460i water softener settings Watts Autotrol 255 (400 Series) User Manual 400 series control settings, 440i control Watts Accessories for water. Resin Tank Size (in Grains) UPFLOW DOWNFLOW; 24,000 Grains: 24 gallons: 58 gallons: 32,000 Grains: Manuals; Customer & Technical Support; SHOP. The Autotrol 268/460i Performa Demand Water Softener Control system for 1 inch plumbing offers flow rates of up to 25 gpm. 268-440i/460i. Programming The Autotrol 460i Water Softeners, Water Actual operating capacity of your softener.Autotrol 255-268/460i softeners are factory set to normally regenerate at 2:00 AM (although you can change this). 742/762 Service Manual Size: 3.3 mb. START to initiate a regeneration. Meter probe disconnected or not fully connected to meter housing. 235.20. There are two mineral tanks in series. The most common bypass systems are the Autotrol Series 1265 bypass valve (1) and plumbed-in globe valves (2).

autotrol model 1550-tc water softener manual download link autotrol model 1550-tc water softener manual read online f Your Specifications. View online (8 pages) or download PDF (118 KB) Autotrol 460i User manual 460i PDF manual download and more Autotrol online manuals Autotrol (1040534) 460I Control Only; 12V 60Hz Calendar override 12 volt operation 7 day variable reserve Autotrol 460TC Timer Control Installation Operation Manual 440i 1040778 Autotrol Parts & Accessories. standard delivery to all UK Mainland Postcodes. 235.20. Line. Guest Cycle (Manual Regeneration) When abnormally high water usage exhausts your water conditioners capacity ahead of schedule, an extra regeneration can be achieved.

The water conditioner consists of a control valve, mineral tank, resin and a salt storage tank. controller. Directions for Sanitizing: Step 1: Backwash the softener and add one 0.5 ounce packet per 4 gallons of water to the brine tank. Grasp timer knob and pull outward. The 460i demand control provides your home with conditioned water based on your familys water usage, and regenerates only when needed. 740/760 Service Manual Size: 3.1 mb. The first has a Autotrol 460i controller (digital) and the tank is smaller. Autotrol water softener prices fit in with the general cost of water softeners as prices typically start upwards of $514. 1) Valve with top distributor fitted.

255/460i/460TC Troubleshooting. 10+. Autotrol > Accessories & Meters > 1265 Bypass Valve; CONTROLLERS. Special Price $401.42. This cost-effective controller is a great for residential and light commercial applications up to 3 cu. Set days of regeneration on skipper wheel (Figure 5). 255-460TC Autotrol 255 Softener Valve, 460 Time Clock 6-Day 460TC Timer replaces 440i HV. Check on Amazon.

Autotrol Brand 255 Valve / 400 Series Controls Guest Cycle (Manual Regeneration) When abnormally high water usage exhausts. Autotrol 268 Performa Water Softener.

To replace the control valve, reverse the above procedure. Removing 440i or 460i for Servicing 1. Unplug the power cord. 2. Remove cover. 3. The control should be in service position (Figure 12). 4. Rotate the locking lever to point up (Figure 13). 5. Pull the end of the camshaft out from the lever and remove the camshaft. Figure 12 Figure 13 6.

Sitemap 1

autotrol 460i manual regeneration